Vedere la pagina 17
2-4
B. ELECTRICAL
1. INTERLOCK WIRE
For electrical installation of the interlock wiring, refer to Figure [2-3] and follow this procedure:
FIGURE [2-3]: INTERLOCK WIRING
a. Route the interlock cable from side channel of the lift enclosure to the 8-Amp circuit breaker
on the pump unit.
b. Strip both interlock wires 1/4" back.
c. Crimp the supplied male connector to the black interlock wire.
d. Crimp the female connector to the white interlock wire.
e. Remove the 18AWG wire from the circuit breaker terminal and attach it to the interlock wire
with male connector (black) at the end.
f. Connect the white interlock wire with female connector to the empty terminal on the 8 Amp
breaker.